Agilent 54825a Service Manual
Agilent HP 54825A / 54825N Oscilloscope Recovery CD ================================================== Agilent Infiniium 548xx Oscilloscope Recovery CD Operating System + Software Version 4.3 For models with the FIC motherboard (i.e. VIN 030-033) Author: Patrick F. Wilbur ================================================== IMPORTANT: LINKING TO THIS PAGE Thank you for your interest in this page! Please feel free to share this resource with your friends; HOWEVER, please do not link directly to the downloads, listed below! Instead, please use the following permalink to this page for all linking/sharing: Floppy Recovery is an Issue The Agilent HP 54825A / 54825N Digital Oscilloscope is an incredibly powerful test and research tool. Although this oscilloscope is now no longer officially supported, Agilent’s technical support staff are extremely helpful in resolving problems, in case you encounter problems and have had one of these scopes for a while or have recently bought a used one from a great remanufacturer.
Unfortunately, if you encounter a failing, failed, or corrupted hard drive and need to re-install its operating system and software, you might be out of luck. Agilent’s technical support team does have some LS-120 recovery floppy media that they can loan, but if it is already loaned to someone else you need to wait your turn. Furthermore, although Agilent has always had LS-120 floppy disk images available, it is highly unlikely that you will easily find an LS-120 drive or LS-120 120 megabyte floppy disks to actually place the recovery disk images on.
Alternative: CD-ROM Recovery (Downloadable Here) The 54825A (54825N) model only has an internal LS-120 floppy drive and no internal CD-ROM drive (plus, you will likely not be able to ever boot from a USB CD-ROM drive with this model). The good news is that, by carefully opening your oscilloscope’s case, you can connect an IDE CD-ROM drive to the oscilloscope’s motherboard via a standard IDE ribbon cable. Even better news is that, although Agilent (previously, before I made this) did not have a recovery CD for this model, I have successfully combined a bootable CD-ROM.iso image with the important files on the LS-120 recovery floppy media images provided by Agilent’s technical support. Directions: • Carefully open oscilloscope chassis. This will involve removing all screws in the back (including those that go through the big rubber feet/things back there, and might also include removing the screws from the handle on the side). • Replace the failed/failing hard drive with a new 2.5″ IDE laptop hard drive. Don’t get something huge like a TB drive.
54825A Infiniium Oscilloscope: 4 Channels. Obsolete View Service Options: This product is no longer available. Manuals, drivers, application. Agilent HP 54825A / 54825N Oscilloscope Recovery CD ===== Agilent Infiniium 548xx Oscilloscope Recovery CD.
Try something smaller than 100 GB. I was successful by using an 80GB 2.5″ IDE laptop hard drive. • Take an (internal) IDE CD-ROM drive, connect the standard IDE ribbon cable to the drive, and connect the other end to the oscilloscope’s motherboard. • Take a spare desktop computer (internal) power supply, set it next to the IDE CD-ROM drive and oscilloscope, and connect one of its Molex power connectors to the power input connector of the CD-ROM drive. This is necessary, because the oscilloscope’s power supply will not have any free power connectors.
Make sure both the oscilloscope and this spare power supply are connected to your AC service. Make sure the spare desktop computer power supply is actually connected to the motherboard of a desktop PC (so you can press the power button on that PC to turn on and off the spare desktop computer power supply). • Download the file you need here: (.iso) (.md5sum). Please DO NOT hot link directly to these files. If you wish to link to or share this, please use the URL of the current page (displayed above, under the section, “IMPORTANT: LINKING TO THIS PAGE”). • Burn the.iso image to a blank CD-ROM (do not simply copy the files from the.iso into a blank CD-ROM folder without burning the.iso file directly, as the bootable information will not carry over).
• Power on the desktop computer (to power on the spare desktop computer power supply), as well as the oscilloscope. Insert the CD-ROM that you burned into the drive.
Witcher 2 Activation Key Generator more. Boot off the CD-ROM. If you experience problems, with a keyboard attached to the oscilloscope, go into your CMOS/BIOS settings and make sure that you have the IDE channel for the CD-ROM drive enabled, and have CD-ROM booting enabled. • Follow the remainder of instructions contained in the README.TXT file (also in th Download Software Synthesizer Untuk Laptop Free more. e.zip file) to begin the re-installation: The Version 4.3 software is designed for units with the FIC motherboard (i.e.